40G单模双纤40KM ER4 CWDM
- 产品描述
- 产品特征
- 技术参数
- 尺寸图
- 订购信息
-
The JHAQC40 is a transceiver module designed for 40km optical communication applications. The design is compliant to 40GBASE-ER4 of the IEEE P802.3ba standard. The module converts 4 inputs channels (ch) of 10Gb/s electrical data to 4 CWDM optical signals, and multiplexes them into a single channel for 40Gb/s optical transmission. Reversely, on the receiver side, the module optically de-multiplexes a 40Gb/s input into 4 CWDM channels signals, and converts them to 4 channel output electrical data.
The central wavelengths of the 4 CWDM channels are 1271, 1291, 1311 and 1331 nm as members of the CWDM wavelength grid defined in ITU-T G694.2. It contains a duplex LC connector for the optical interface and a 38-pin connector for the electrical interface. To minimize the optical dispersion in the long-haul system, single-mode fiber (SMF) has to be applied in this module.
The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.
The module operates from a single +3.3V power supply and LVCMOS/LVTTL global control signals such as Module Present, Reset, Interrupt and Low Power Mode are available with the modules. A 2-wire serial interface is available to send and receive more complex control signals and to obtain digital diagnostic information. Individual channels can be addressed and unused channels can be shut down for maximum design flexibility.
The JHAQC40 is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference. The module offers very high functionality and feature integration, accessible via a two-wire serial interface.
-
Features
² 4 CWDM lanes MUX/DEMUX design
² Up to 11.2Gbps per channel bandwidth
² Aggregate bandwidth of > 40Gbps
² Duplex LC connector
² Compliant with 40G Ethernet IEEE802.3ba and 40GBASE-ER4 Standard
² QSFP MSA compliant
² APD photo-detector
² Up to 40 km transmission
² Compliant with QDR/DDR Infiniband data rates
² Single +3.3V power supply operating
² Built-in digital diagnostic functions
² Temperature range 0°C to 70°C
² RoHS Compliant Part
Applications:
² Rack to rack
² Data centers Switches and Routers
² Metro networks
² Switches and Routers
² 40G BASE-ER4 Ethernet Links
-
Absolute Maximum Ratings
Parameter
Symbol
Min.
Typical
Max.
Unit
Storage Temperature
TS
-40
+85
°C
Supply Voltage
VCCT, R
-0.5
4
V
Relative Humidity
RH
0
85
%
Recommended Operating Environment:
Parameter
Symbol
Min.
Typical
Max.
Unit
Case operating Temperature
TC
0
+70
°C
Supply Voltage
VCCT, R
+3.13
3.3
+3.47
V
Supply Current
ICC
1000
mA
Power Dissipation
PD
3.5
W
Electrical Characteristics (TOP = 0 to 70 °C, VCC = 3.13 to 3.47 Volts
Parameter
Symbol
Min
Typ
Max
Unit
Note
Data Rate per Channel
-
10.3125
11.2
Gbps
Power Consumption
-
2.5
3.5
W
Supply Current
Icc
0.75
1.0
A
Control I/O Voltage-High
VIH
2.0
Vcc
V
Control I/O Voltage-Low
VIL
0
0.7
V
Inter-Channel Skew
TSK
150
Ps
RESETL Duration
10
Us
RESETL De-assert time
100
ms
Power On Time
100
ms
Transmitter
Single Ended Output Voltage Tolerance
0.3
4
V
1
Common mode Voltage Tolerance
15
mV
Transmit Input Diff Voltage
VI
150
1200
mV
Transmit Input Diff Impedance
ZIN
85
100
115
Data Dependent Input Jitter
DDJ
0.3
UI
Receiver
Single Ended Output Voltage Tolerance
0.3
4
V
Rx Output Diff Voltage
Vo
370
600
950
mV
Rx Output Rise and Fall Voltage
Tr/Tf
35
ps
1
Total Jitter
TJ
0.3
UI
Note:
1. 20~80%
Optical Parameters(TOP = 0 to 70 °C, VCC = 3.0 to 3.6 Volts)
Parameter
Symbol
Min
Typ
Max
Unit
Ref.
Transmitter
Wavelength Assignment
L0
1264.5
1271
1277.5
nm
L1
1284.5
1291
1297.5
nm
L2
1304.5
1311
1317.5
nm
L3
1324.5
1331
1337.5
nm
Side-mode Suppression Ratio
SMSR
30
-
-
dB
Total Average Launch Power
PT
-
-
8.3
dBm
Average Launch Power, each Lane
-3
-
5
dBm
TDP, each Lane
TDP
2.3
dB
Extinction Ratio
ER
3.5
6.0
dB
Transmitter Eye Mask Definition {X1, X2, X3, Y1, Y2, Y3}
{0.25, 0.4, 0.45, 0.25, 0.28, 0.4}
Optical Return Loss Tolerance
-
-
20
dB
Average Launch Power OFF Transmitter, each Lane
Poff
-30
dBm
Relative Intensity Noise
Rin
-128
dB/HZ
1
Optical Return Loss Tolerance
-
-
12
dB
Receiver
Damage Threshold
THd
3
dBm
1
Average Power at Receiver Input, each Lane
R
-21
-6
dBm
Receive Electrical 3 dB upper Cut off Frequency, each Lane
12.3
GHz
RSSI Accuracy
-2
2
dB
Receiver Reflectance
Rrx
-26
dB
Receiver Power (OMA), each Lane
-
-
3.5
dBm
Receive Electrical 3 dB upper Cutoff Frequency, each Lane
12.3
GHz
LOS De-Assert
LOSD
-25
dBm
LOS Assert
LOSA
-35
dBm
LOS Hysteresis
LOSH
0.5
dB
Note
1. 12dB Reflection
Diagnostic Monitoring Interface
Digital diagnostics monitoring function is available on all QSFP+ ER4. A 2-wire serial interface provides user to contact with module. The structure of the memory is shown in flowing. The memory space is arranged into a lower, single page, address space of 128 bytes and multiple upper address space pages. This structure permits timely access to addresses in the lower page, such as Interrupt Flags and Monitors. Less time critical time entries, such as serial ID information and threshold settings, are available with the Page Select function. The interface address used is A0xh and is mainly used for time critical data like interrupt handling in order to enable a one-time-read for all data related to an interrupt situation. After an interrupt, IntL has been asserted, the host can read out the flag field to determine the affected channel and type of flag.



EEPROM Serial ID Memory Contents (A0h)
Data
Address
Length
(Byte)Name of
Length
Description and Contents
Base ID Fields
128
1
Identifier
Identifier Type of serial Module(D=QSFP+)
129
1
Ext. Identifier
Extended Identifier of Serial Module(90=2.5W)
130
1
Connector
Code of connector type(7=LC)
131-138
8
Specification compliance
Code for electronic compatibility or optical compatibility(40GBASE-LR4)
139
1
Encoding
Code for serial encoding algorithm(5=64B66B)
140
1
BR, Nominal
Nominal bit rate, units of 100 MBits/s(6C=108)
141
1
Extended rateselect Compliance
Tags for extended rate select compliance
142
1
Length(SMF)
Link length supported for SMF fiber in km (28=40KM)
143
1
Length(OM3 50um)
Link length supported for EBW 50/125um fiber(OM3), units of 2m
144
1
Length(OM2 50um)
Link length supported for 50/125um fiber(OM2), units of 1m
145
1
Length(OM1 62.5um)
Link length supported for 62.5/125um fiber (OM1), units of 1m
146
1
Length(Copper)
Link length of copper or active cable, unites of 1m Link length supported for 50/125um fiber (OM4), units of 2m when Byte 147 declares 850nm VCSEL as defined in Table 37
147
1
Device tech
Device technology
148-163
16
Vendor name
QSFP+ vendor name: JHA(ASCII)
164
1
Extended Module
Extended Module codes for InfiniBand
165-167
3
Vendor OUI
QSFP+ vendor IEEE company ID(000840)
168-183
16
Vendor PN
Part number: JHAQC40 (ASCII)
184-185
2
Vendor rev
Revision level for part number provided by vendor (ASCII) (X1)
186-187
2
Wave length or Copper cable Attenuation
Nominal laser wavelength (wavelength=value/20 in nm) or copper cable attenuation in dB at 2.5GHz (Adrs 186) and 5.0GHz (Adrs 187) (65A4=1301)
188-189
2
Wavelength tolerance
Guaranteed range of laser wavelength(+/- value) from nominal
wavelength. (wavelength Tol.=value/200 in nm) (1C84=36.5)190
1
Max case temp.
Maxinum case temperature in degrees C (70)
191
1
CC_BASE
Check code for base ID fields (addresses 128-190)
Extended ID fields
192-195
4
Options
Rate Select, TX Disable, Tx Fault, LOS, Warning indicators for: Temperature, VCC, RX, power, TX Bias
196-211
16
Vendor SN
Serial number provided by vendor (ASCII)
212-219
8
Date Code
Vendor's manufacturering date code
220
1
Diagnostic Monitoring Type
Indicates which types of diagnostic monitoring are implemented (if any) in the Module. Bit 1, 0 Reserved (8=Average Power)
221
1
Enhanced Options
Indicates which optional enhanced features are implemented in the Module.
222
1
Reserved
223
1
CC_EXT
Check code for the Extended ID Fields (addresses 192-222)
Vendor Specific ID Fields
224-255
32
Vendor Specific EEPROM
Timing for Soft Control and Status Functions
Parameter
Symbol
Max
Unit
Conditions
Initialization Time
t_init
2000
ms
Time from power on1, hot plug or rising edge of Reset until the module is fully functional2
Reset Init Assert Time
t_reset_init
2
μs
A Reset is generated by a low level longer than the minimum reset pulse time present on the ResetL pin.
Serial Bus Hardware Ready Time
t_serial
2000
ms
Time from power on1 until module responds to data transmission over the 2-wire serial bus
Monitor Data Ready
Time
t_data
2000
ms
Time from power on1 to data not ready, bit 0 of Byte 2, deasserted and IntL asserted
Reset Assert Time
t_reset
2000
ms
Time from rising edge on the ResetL pin until the module is fully functional2
LPMode Assert Time
ton_LPMode
100
μs
Time from assertion of LPMode (Vin:LPMode =Vih) until module power consumption enters lower Power Level
IntL Assert Time
ton_IntL
200
ms
Time from occurrence of condition triggering IntL until Vout:IntL = Vol
IntL Deassert Time
toff_IntL
500
μs
toff_IntL 500 μs Time from clear on read3 operation of associated flag until Vout:IntL = Voh. This includes deassert times for Rx LOS, Tx Fault and other flag bits.
Rx LOS Assert Time
ton_los
100
ms
Time from Rx LOS state to Rx LOS bit set and IntL asserted
Flag Assert Time
ton_flag
200
ms
Time from occurrence of condition triggering flag to associated flag bit set and IntL asserted
Mask Assert Time
ton_mask
100
ms
Time from mask bit set4 until associated IntL assertion is inhibited
Mask De-assert Time
toff_mask
100
ms
Time from mask bit cleared4 until associated IntlL operation resumes
ModSelL Assert Time
ton_ModSelL
100
μs
Time from assertion of ModSelL until module responds to data transmission over the 2-wire serial bus
ModSelL Deassert Time
toff_ModSelL
100
μs
Time from deassertion of ModSelL until the module does not respond to data transmission over the 2-wire serial bus
Power_over-ride or
Power-set Assert Time
ton_Pdown
100
ms
Time from P_Down bit set 4 until module power consumption enters lower Power Level
Power_over-ride or Power-set De-assert Time
toff_Pdown
300
ms
Time from P_Down bit cleared4 until the module is fully functional3
Note:
1. Power on is defined as the instant when supply voltages reach and remain at or above the minimum specified value.
2. Fully functional is defined as IntL asserted due to data not ready bit, bit 0 byte 2 de-asserted.
3. Measured from falling clock edge after stop bit of read transaction.
4. Measured from falling clock edge after stop bit of write transaction.
Transceiver Block Diagram


Diagram of Host Board Connector Block Pin Numbers and Name
Pin Description
Pin
Logic
Symbol
Name/Description
Ref.
1
GND
Ground
1
2
CML-I
Tx2n
Transmitter Inverted Data Input
3
CML-I
Tx2p
Transmitter Non-Inverted Data output
4
GND
Ground
1
5
CML-I
Tx4n
Transmitter Inverted Data Output
6
CML-I
Tx4p
Transmitter Non-Inverted Data Output
7
GND
Ground
1
8
LVTTL-I
ModSelL
Module Select
9
LVTTL-I
ResetL
Module Reset
10
VccRx
+3.3V Power Supply Receiver
2
11
LVCMOS-I/O
SCL
2-Wire Serial Interface Clock
12
LVCMOS-I/O
SDA
2-Wire Serial Interface Data
13
GND
Ground
1
14
CML-O
Rx3p
Receiver Inverted Data Output
15
CML-O
Rx3n
Receiver Non-Inverted Data Output
16
GND
Ground
1
17
CML-O
Rx1p
Receiver Inverted Data Output
18
CML-O
Rx1n
Receiver Non-Inverted Data Output
19
GND
Ground
1
20
GND
Ground
1
21
CML-O
Rx2n
Receiver Inverted Data Output
22
CML-O
Rx2p
Receiver Non-Inverted Data Output
23
GND
Ground
1
24
CML-O
Rx4n
Receiver Inverted Data Output
25
CML-O
Rx4p
Receiver Non-Inverted Data Output
26
GND
Ground
1
27
LVTTL-O
ModPrsL
Module Present
28
LVTTL-O
IntL
Interrupt
29
VccTx
+3.3V Power Supply Transmitter
2
30
Vcc1
+3.3V Power Supply
2
31
LVTTL-I
LPMode
Low Power Mode
32
GND
Ground
1
33
CML-I
Tx3p
Transmitter Inverted Data Output
34
CML-I
Tx3n
Transmitter Non-Inverted Data Output
35
GND
Ground
1
36
CML-I
Tx1p
Transmitter Inverted Data Output
37
CML-I
Tx1n
Transmitter Non-Inverted Data Output
38
GND
Ground
1
Notes:
1. GND is the symbol for single and supply(power) common for QSFP modules, All are common within the QSFP module and all module voltages are referenced to this potential otherwise noted. Connect these directly to the host board signal common ground plane. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
2. VccRx, Vcc1 and VccTx are the receiver and transmitter power suppliers and shall be applied concurrently. Recommended host board power supply filtering is shown below. VccRx, Vcc1 and VccTx may be internally connected within the QSFP transceiver module in any combination. The connector pins are each rated for maximum current of 500mA.
Recommended Circuit

-
Mechanical Dimensions

-
JHAQC4040Gb/s 40km QSFP+ Transceiver Hot Pluggable, Duplex LC Connector, Single mode
上一页